Refrigeration Systems

Walk-in coolers, walk-in freezers, reach-ins, prep tables, keg boxes. If it keeps food or beer cold, we work on it.

  • Walk-in cooler & freezer repair
  • Compressor and condenser service
  • Evaporator and fan motor issues
  • Door gaskets, heaters, and seals
  • Defrost systems and controls
  • Temp verification under load

Glycol Cooling Systems

Long-draw draft systems depend on glycol to keep beer cold from keg to tap.

  • Glycol bath chiller service
  • Pump and circulation issues
  • Trunk line insulation
  • Level and concentration checks
  • Tower temperature verification

Draft Beverage Systems

From keg boxes to long-draw glycol systems. Beer, wine, cocktails, and nitro coffee.

  • Beer line cleaning service
  • Pressure balance verification
  • Regulator, coupler, FOB service
  • Tower and faucet repair
  • Keg box and kegerator setup
  • Nitro cold brew systems
Advanced Capability

Extended Diagnostics

When a unit is down or failure is suspected, we deploy advanced diagnostic tools to identify the problem quickly and accurately.

ELECTRICAL DIAGNOSTICS COMPRESSOR 7.2A V 238V SUPPLY OK 42µF RATED: 45µF ±6% WITHIN SPEC

Electrical Load Testing

Live voltage verification, compressor amperage under load, capacitor testing, contactor condition assessment. Identifies electrical issues before they cause compressor failure.

FLIR THERMAL IMAGING HOT 180°F 120°F 80°F 176°F BLOCKED AIRFLOW

FLIR Thermal Imaging

Identifies hot spots, blocked airflow, insulation failures, and overheating components without disassembly. See problems invisible to the naked eye.

ELECTRONIC LEAK DETECTION LEAK R-404A PPM SENSITIVITY DETECTION

Electronic Leak Detection

Parts-per-million sensitivity for refrigerant leak detection. Pinpoints leaks in the sealed system before they cause complete charge loss.

GLYCOL SPECTROMETRY SAMPLE 32% CONCENTRATION 32% TARGET: 30-35% ✓ OPTIMAL FREEZE POINT -8°F PROPYLENE GLYCOL ANALYSIS

Glycol Spectrometry

Verifies glycol concentration and freeze point. Ensures your draft system is protected and cooling efficiently.

Note: Extended diagnostics are deployed when a unit is down or failure is suspected. These advanced tests are not included in standard PM visits but are available when needed to identify problems quickly.

Draft Line Cleaning

A full caustic and acid cycle cleaning can be added to your account as a bi-weekly service. More access means more contact, faster diagnosis, and better prevention. We partner with the city's top line cleaners at competitive pricing.

Ask About Line Cleaning

Have a Question?

Whether it's a warm reach-in, a foamy pour, or equipment you inherited and don't understand, we can help.

Get in Touch